how many kg lp gas spent 300 kg per hour steam boiler

wns boiler picture

1-20 ton gas/oil fired boiler

Capacity: 1-20 ton/h

Pressure: 0.7-2 Mpa

Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

szs boiler picture

7-70 MW gas/oil fired hot water boiler

Capacity: 7-70 MW

Pressure: 1.0-1.6 Mpa

Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, hospital, colleges and universities.

szl boiler picture

2.8-29mw coal fired boiler

Capacity: 2.8-29mw

Pressure: 1.0-1.25 Mpa

Fuel: Bituminous coal, lean coal, anthracite

Industries: Heating, hotels, schools, hospitals

yyw boiler picture

horizontal thermal fluid heater

Capacity: 700 - 14000 kw

Pressure: 0.8 - 1.0 Mpa

Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

dzl boiler picture

1-20 ton biomass fired boiler

Capacity: 1-20 ton/h

Pressure: 0.7-2.5 Mpa

Fuel: Biomass particles

Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Steam Calculators: Boiler Calculator

Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.

Boiler for Oil & Gas - 300 kg/hr to 750 kg/hr- Minimax Boilers

Oil and Gas Fired Boilers DynaMax Small Industrial Boilers (300 kg/hr) Modular Boilerhouse (500-6000 kg/hr) MiniMax Compact Packaged Boiler (500kg/hr and 750kg/hr) Marshall B Series Industrial Boilers (1000-5000kg/hr) Marshall C Series Packaged Boilers (6000-25000 kg/hr) Exhaust Gas and Heat Recovery Boiler

conversion m3/hr to kg/hr for (lpg) gas - OnlineConversion Forums

Re: conversion m3/hr to kg/hr for (lpg) gas [ want to know how to convert m3 per hour to kilograms per hour for compressor used for LPG fuel used in cars. at 1 bar gas inlet pressure. Normal usage of 2200m3/hr at 1 bar pressure is to be converted in to Kcl/kg

Steam Capacity Conversion Table | Industrial Controls

How many lbs per hour of steam is need to heat 40 gallons per minute flow rate of water from 60 ° F to 180 ° F? Sizing a Boiler Feed Pump Receiver The receiver tank should be able to hold five minutes worth of condensate for boilers up to 200 BHP and 10 minutes of condensate for boilers over 200 BHP.

How much fuel is needed to produce 1 kg of steam? - Quora

Energy density of diesel = 48MJ/kg. lets assume only 90% of the energy is converted to useful heat. Therefore, the amount of coal = 2573950/(35000000 x.9) = 0.082 kg. the amount of diesel = 2573950/ (48000000 x .9) = 0.060 kg. By this calculation we need around 80g of coal or 60g of coal to produce 1kg of steam from water at 25 c.

How much fuel required for 1TPH boiler? - Quora

Boiler Capacity - 1000 kg/hr. Steam Pressure - 10.5 kg/cm2(g) Steam Temperature - 185.5 Deg c (Saturated Steam)- You will get this value in steam table. Enthalpy of Saturated Steam - 664.2 kcal/kg-You will get this value in steam table. Enthalpy of Feed water - 105 kcal/kg - You will get this value in steam table. Fuel - Bagasse with 50% moisture

CONVERSION OF BOILER IN KG/H AND KW - cni.co.th

CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566 2350 3130 3915 4700 5480

LPG (propane) Conversions: Gas kg, Litres, MJ, kWh & m³

LPG (propane) Conversions: Gas kg, Litres, MJ, kWh & m³ Megajoules per Hour (MJ/hr) ratings on appliances actually indicate the gas consumption of the appliance

lb/hour - Pound Per Hour. Conversion Chart / Flow Rate by

This is a conversion chart for pound per hour (U.S. and British Imperial). To switch the unit simply find the one you want on the page and click it. You can also go to the universal conversion page. 2: Enter the value you want to convert (pound per hour). Then click the Convert Me button.

Boiler Horsepower - Engineering ToolBox

A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) - with feed water at pressure 0 psig and temperature 212 o F.

Get Price And Support

Solutions